Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	37
Date	08/12/14
Start Time	10:33:54
Diameter Midpoint
 10.9	569.79
 11.3	14591.9
 11.8	108412
 12.2	148780
 12.6	175923
 13.1	214313
 13.6	253709
 14.1	293021
 14.6	330132
 15.1	382228
 15.7	432145
 16.3	486306
 16.8	536976
 17.5	596962
 18.1	646501
 18.8	700747
 19.5	760857
 20.2	799388
 20.9	829379
 21.7	864426
 22.5	884045
 23.3	907762
 24.1	908688
 25.0	911942
 25.9	903627
 26.9	881171
 27.9	837110
 28.9	786842
 30.0	722563
 31.1	661064
 32.2	588324
 33.4	496272
 34.6	418852
 35.9	344148
 37.2	274325
 38.5	212435
 40.0	161837
 41.4	118632
 42.9	83833.6
 44.5	57210.9
 46.1	38554.8
 47.8	24887
 49.6	16065.2
 51.4	10043.5
 53.3	6288.14
 55.2	3965.8
 57.3	2346.33
 59.4	1497.78
 61.5	1021.33
 63.8	671.12
 66.1	466.237
 68.5	371.582
 71.0	238.564
 73.7	233.035
 76.4	195.822
 79.1	167.06
 82.0	191.433
 85.1	140.006
 88.2	131.06
 91.4	121.596
 94.7	132.584
 98.2	146.829
101.8	98.2046
105.5	103.307
109.4	114.005
113.4	69.734
117.6	123.478
121.9	83.9489
126.3	85.6696
131.0	82.8281
135.8	79.3215
140.7	77.8503
145.9	58.0783
151.2	90.7388
156.8	71.0765
162.5	64.8256
168.5	74.655
174.7	68.9396
181.1	35.014
187.7	69.0517
194.6	61.7501
201.7	56.1768
209.1	58.2347
216.7	47.5539
224.7	60.328
232.9	41.886
241.4	41.2069
250.3	53.8077
259.5	53.005
269.0	32.6082
278.8	47.9768
289.0	47.2207
299.6	29.876
310.6	25.9595
322.0	31.3196
333.8	31.9239
346.0	17.742
358.7	29.0528
371.8	13.8158
385.4	26.0198
399.5	17.215
414.2	19.9746
429.4	7.09019
445.1	15.7824
461.4	17.1381
478.3	3.45296
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1735
High Voltage	9848.5
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	23.3076
Mean(nm)	24.0702
Geo. Mean(nm)	23.0648
Mode(nm)	25.0287
Geo. Std. Dev.	1.3396
Total Concentration(#/cm)	1.98463e+007
Comment	